| 是否提供加工定制: | 是 | 类型: | 浮动盘管换热器 |
| 品牌: | 徐州四方 | 重量: | 550(kg) |
| 用途: | 传热 | 传热方式: | 间壁式换热器 |
型号 | PFK0.35 | PFK0.53 | PFK0.7 | PFK1.05 | PFK1.4 | PFK1.75 | PFK2.1 | PFK2.8 | PFK3.3 | PFK3.7 | PFK4.2 | PFK4.9 | PFK5.6 |
基本换热量MW | 0.35 | 0.53 | 0.7 | 1.05 | 1.40 | 1.75 | 2.1 | 2.8 | 3.3 | 3.7 | 4.2 | 4.9 | 5.6 |
适用蒸汽压力MPa | 0.1~0.6 | ||||||||||||
适用供水压力MPa | 0.1~0.8 | ||||||||||||
耗汽量t/h | 0.54 | 0.82 | 1.09 | 1.63 | 2.18 | 2.72 | 3.26 | 4.35 | 5.06 | 5.79 | 635 | 7.60 | 8.70 |
出水量t/h | 12 | 18 | 24 | 36 | 48 | 60 | 72 | 96 | 112 | 128 | 114 | 168 | 192 |
出水/进水温度℃ | 65/50 | ||||||||||||
蒸汽/凝水管径MM | 65/40 | 65/40 | 80/40 | 80/40 | 100/50 | 125/50 | 125/50 | 125/65 | 125/65 | 125/65 | 150/80 | 150/80 | 150/80 |
进水/出水管径MM | 70/70 | 70/70 | 80/80 | 100/100 | 100/100 | 125/125 | 125/125 | 150/150 | 150/150 | 150/150 | 200/200 | 200/200 | 200/200 |
壳程阻力KPa | 1~25 | ||||||||||||
外形尺寸MM | ф500-1840 | ф500*2190 | ф500-2290 | ф500-2460 | ф500*2560 | ф600*2710 | ф600-2790 | ф700*3010 | ф700*2635 | ф700*3035 | ф800*2700 | ф800*2900 | ф800*3100 |
运行重量Kg | ~480 | ~650 | ~750 | ~1000 | ~1200 | ~1300 | ~1800 | ~2000 | ~2200 | ~2350 | ~2550 | ~2700 | ~2900 |
采暖面积 | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 28000 | 3200 | 36000 | 42000 | 48000 |
浮动盘管换热器主要原理:换热器的热媒通过换热管,冷媒处于换热管和壳体之间,换热管加工成宝塔状盘形弹性管束,当热媒及蒸汽进入盘管,由于关内外温差较大,盘管产生扰动击打冷媒,增加换热效率,同时由于盘管与冷媒撞击,水垢不容易附着到盘管上,滑落到壳体底部,由排污阀排除。有效解决了水垢问题。
产品描述:PF型浮动盘管式换热器用于汽车--水换热,它的传热元件是悬臂式浮动盘管结构。在加热过程中,由于盘管内蒸汽离心力的作用,使盘管束产生一种高频震动,促使被加热介质产生骚动,破坏层流体传热,产生 高传热能力,传热系统K为3000W/m².°C。同时由于盘管为悬臂自由端,胀缩自如,产生高频振动,使碱性附着物自动离开管壁,形成自动脱垢的独有特性。
主要性能:
1.传热效率高
2.设备结构紧凑,体积小,占地面积小,不需预留管束抽出空间。
3.解决了传统除垢繁琐工艺,可以自动除垢。
4.外壳温度低,热损失小,具有凝结水过冷装置,在热水供应中选用时,可不装输水设备,节能、省时,具有明显的经济效益和社会效益。